Plumb context from the API down to libnet driver method `CreateNetwork`,
and add an OTel span to the bridge driver's `createNetwork` method.
Include a few attributes describing the network configuration (e.g.
IPv4/IPv6, ICC, internal and MTU).
A new util function, `RecordStatus`, is added to the `otelutil` package
to easily record any error, and update the span status accordingly.
Signed-off-by: Albin Kerouanton <albinker@gmail.com>
To support this, a new netlabel is added: `com.docker.network.endpoint.ifname`.
It gives the ability to specify the interface name to be set by
netdrivers when the interface is added / moved into the container's
network namespace.
All builtin netdrivers support it.
Signed-off-by: Albin Kerouanton <albinker@gmail.com>
Now a gratuitous/unsolicted ARP is sent, there's no need to
use an IPv4-based MAC address to preserve arp-cache mappings
between an endpoint's IP addresses and its MAC addresses.
Because a random MAC address is used for the default bridge,
it no longer makes sense to derive container IPv6 addresses
from the MAC address. This "postIPv6" behaviour was needed
before IPv6 addresses could be configured, but not now. So,
IPv6 addresses will now be IPAM-allocated on the default
bridge network, just as they are for user-defined bridges.
Signed-off-by: Rob Murray <rob.murray@docker.com>
Before that change, we were passing the datastore to network drivers
through a `map[string]interface{}`. Then, each driver that needed the
store would cast the datastore to the correct type.
This was not a good design, as it was not clear which drivers were using
the store and which were not. Not all unit tests were passing the store,
leading to logs about uninitialized store being written.
This change makes the store a parameter of the `RegisterX` functions.
All unit tests are now passing a valid datastore to the drivers. A new
testutil func is added for that purpose.
Signed-off-by: Albin Kerouanton <albinker@gmail.com>
A recent change to the vishvananda/netlink package exposes
NLM_F_DUMP_INTR in some netlink responses as an EINTR (with
no data).
Retry the requests when that happens, up to five times, before
returning the error. The limit of five is arbitrary, on most
systems a single retry will be rare but, there's no guarantee
that a retry will succeed. So, on a very busy or misbehaving
system the error may still be returned. In most cases, this
will lead to failure of the operation being attempted (which
may lead to daemon startup failure, network initialisation
failure etc).
Signed-off-by: Rob Murray <rob.murray@docker.com>
Make the behaviour enabled by env var DOCKER_BRIDGE_PRESERVE_KERNEL_LL
the default...
- don't remove kernel assigned link-local addresses
- or any address in fe80::/64
- don't assign fe80::1 to a bridge
Signed-off-by: Rob Murray <rob.murray@docker.com>
If IPv6 is enabled for a bridge network, by the time configuration
is applied, the bridge will always have an address. Assert that, by
raising an error when the configuration is validated.
Use that to simplify the logic used to calculate which addresses
should be assigned to a bridge. Also remove a redundant check in
setupGatewayIPv6() and the error associated with it.
Fix unit tests that enabled IPv6, but didn't supply an IPv6 IPAM
address/pool. Before this change, these tests passed but silently
left the bridge without an IPv6 address.
(The daemon already ensured there was an IPv6 address, this change
does not add a new restriction on config at that level.)
Signed-off-by: Rob Murray <rob.murray@docker.com>
This makes it easier to spot if code is only used on Linux. Note that "all of"
the bridge driver is Linux-only.
Signed-off-by: Sebastiaan van Stijn <github@gone.nl>