This is a planned follow-on from #10721 primarily at the request of
@fuweid, exchanging MNT_DETACH at unmount time for MOUNT_ATTR_RDONLY at
mount time. The effect is to increase risk of unmount failure due to
EBUSY (as observed in the wild) but add an additional protection that the
then-leaked bind mount does not act as a conduit for inadvertent modification
of the underlying data, including our own efforts to clean up the mountpoint.
Tests covering the lifecycle of the temporary idmap mounts and integrity
of the underlying lower layer data is also included in the normal and
failed-unmount case.
Fixes#10704
Signed-off-by: Mike Baynton <mike@mbaynton.com>
The cri image service init has a bug where, after getting FSPath
for snapshotter_i, it stores it under defaultSnapshotter instead
of snapshotter_i.
Also make a few other refactor:
1. Dedup the snapshotRoot loading for defaultSnapshotter
2. Remove some unnecessary logic in RuntimePlatforms for-loop
Signed-off-by: Jin Dong <djdongjin95@gmail.com>
* container_update_resources.go: it is Windows and Linux that need special handling
* local*.go: all platforms use the same list of tasks
* temp_unix.go/temp_unsupported.go: Darwin is a Unix
* util_unix.go/util_unsupported.go: use generic unix tag
The only user-visible effect of these changes is that tempMountLocation is now properly handled on Darwin
Signed-off-by: Marat Radchenko <marat@slonopotamus.org>
Other similar events were already moved to the metadata store. The
metadata store has more information that can be used for a future
content created event.
Signed-off-by: Derek McGowan <derek@mcg.dev>
- combine consecutive "WithField" calls to "WithFields", as multiple
calls is known to be expensive.
- include a "snapshotter" field in logs to allow correlating actions
with specific snapshotters.
Signed-off-by: Sebastiaan van Stijn <github@gone.nl>
A contentstore can be created on top of readonly path and
should not fail unless there is an attempt to write into it.
Currently this fails because new ingest directory is created
always, meaning for example that you can't create a store to
read blobs from OCI layout without it contaminating the OCI
layout files.
Signed-off-by: Tonis Tiigi <tonistiigi@gmail.com>
Uses the new github.com/containerd/errdefs/pkg module which is intended
to hold less stable utility functions separately from the stable
github.com/containerd/errdefs error types.
Includes temporary update to hcsshim until a release is cut there
Signed-off-by: Derek McGowan <derek@mcg.dev>
Makes the pprof server a plugin and also gates by the `shim_tracing`
build tag (like otel is).
With this change, `net/http` is no longer a dependency in the shim.
Signed-off-by: Brian Goff <cpuguy83@gmail.com>
Core should not have a dependency on API types.
This was causing a transative dependency on grpc when importing the core
snapshots package.
Signed-off-by: Brian Goff <cpuguy83@gmail.com>
Update the local content plugin to register itself in a consistent way
as other plugins. This also allows the separate package to define its
own configuration more cleanly.
Signed-off-by: Derek McGowan <derek@mcg.dev>
Commit 8437c567d8 migrated the use of the
userns package to the github.com/moby/sys/user module.
After further discussion with maintainers, it was decided to move the
userns package to a separate module, as it has no direct relation with
"user" operations (other than having "user" in its name).
This patch migrates our code to use the new module.
Signed-off-by: Sebastiaan van Stijn <github@gone.nl>
The userns package in libcontainer was integrated into the moby/sys/user
module at commit [3778ae603c706494fd1e2c2faf83b406e38d687d][1].
This patch deprecates the containerd fork of that package, and adds it as
an alias for the moby/sys/user/userns package.
[1]: 3778ae603c
Signed-off-by: Sebastiaan van Stijn <github@gone.nl>
The /var/lib/containerd/io.containerd.grpc.v1.introspection/uuid file
stores a UUID to identify the particular containerd daemon responding to
requests. The file should either exist with a UUID, or not exist.
However, it has been observed that the file can be truncated with 0
bytes, which will then fail to be parsed as a valid UUID.
As a defensive practice, detect a 0-length file and overwrite with a new
UUID rather than failing.
Fixes: https://github.com/containerd/containerd/issues/10491
Signed-off-by: Samuel Karp <samuelkarp@google.com>
This functionality is not directly related to containerd and could move
to external package at some point.
Signed-off-by: Derek McGowan <derek@mcg.dev>
A nil CRIImplementation field can cause a nil pointer dereference and
panic during startup recovery.
Prior to this change, the nri.API struct would have a nil cri
(CRIImplementation) field after nri.NewAPI until nri.Register was
called. Register is called mid-way through initialization of the CRI
plugin, but recovery for containers occurs prior to that. Container
recovery includes establishing new exit monitors for existing containers
that were discovered. When a container exits, NRI plugins are given the
opportunity to be notified about the lifecycle event, and this is done
by accessing that CRIImplementation field inside the nri.API. If a
container exits prior to nri.Register being called, access to the
CRIImplementation field can cause a panic.
Here's the call-path:
* The CRI plugin starts running
[here](ae71819c4f/pkg/cri/server/service.go (L222))
* It then [calls into](ae71819c4f/pkg/cri/server/service.go (L227))
`recover()` to recover state from previous runs of containerd
* `recover()` then attempts to recover all containers through
[`loadContainer()`](ae7d74b9e2/internal/cri/server/restart.go (L175))
* When `loadContainer()` finds a container that is still running, it waits
for the task (internal containerd object) to exit and sets up
[exit monitoring](ae7d74b9e2/internal/cri/server/restart.go (L391))
* Any exit that then happens must be
[handled](ae7d74b9e2/internal/cri/server/events.go (L145))
* Handling an exit includes
[deleting the Task](ae7d74b9e2/internal/cri/server/events.go (L188))
and specifying [`nri.WithContainerExit`](ae7d74b9e2/internal/cri/nri/nri_api_linux.go (L348))
to [notify](ae7d74b9e2/internal/cri/nri/nri_api_linux.go (L356))
any subscribed NRI plugins
* NRI plugins need to know information about the pod (not just the sandbox),
so before a plugin is notified the NRI API package
[queries the Sandbox Store](ae7d74b9e2/internal/cri/nri/nri_api_linux.go (L232))
through the CRI implementation
* The `cri` implementation member field in the `nri.API` struct is set as part of the
[`Register()`](ae7d74b9e2/internal/cri/nri/nri_api_linux.go (L66)) method
* The `nri.Register()` method is only called
[much further down in the CRI `Run()` method](ae71819c4f/pkg/cri/server/service.go (L279))
Signed-off-by: Samuel Karp <samuelkarp@google.com>
Implement calls to the fsverity kernel module, allowing containerd to
enable fsverity on blob data in the content store. This causes fsverity
to veirfy the integrity of blob data when the blob is read.
Signed-off-by: James Jenkins <James.Jenkins@ibm.com>